T&S 100G dense wavelength division optical add/drop multiplexing module has flexible wavelength configuration, which can upload or download multiple DWDM wavelengths in the C-band or L-band range, and can meet various bus and ring DWDM groups Network models, such as long-distance high-speed rail communication systems, inter-city backbone networks and other application scenarios.
Automatic Optical alignment
Optical path epoxy-free
Low insert loss & high isolation
Telcordia GR-1221-Core qualified
RoHS compliant
DWDM channel add/drop
Metro access system
PON System
OXC system
Parameters | Unit | Specification | ||||
Central Wavelength | nm | ITU-T Grid | ||||
Channel Spacing | GHz | 100 | ||||
Channel Pass band | nm | ITU ±0.11 | ||||
Center wavelength accuracy | nm | λc±0.05 | ||||
Channel Count | CH | 1 | 2 | 4 | 8 | |
Insertion Loss | In to Drop@λDrop | dB | ≤1.2 | ≤1.6 | ≤2.5 | ≤4.0 |
Add to Out @λAdd | dB | ≤1.2 | ≤1.6 | ≤2.5 | ≤4.0 | |
In to Out @λOther | dB | ≤1.2 | ≤2.0 | ≤3.2 | ≤5.7 | |
Pass band Ripple | dB | ≤0.5 | ||||
Isolation | Adjacent Channel | dB | >25 | |||
Non-Adjacent Channel | dB | ≥35 | ||||
Insertion Loss Thermal Stability | dB/℃ | ≤0.003 | ||||
Wavelength Thermal Stability | nm/℃ | ≤0.002 | ||||
Return Loss | dB | ≥45 | ||||
Polarization Dependent Loss | dB | ≤0.25 | ||||
Polarization Mode Dispersion | Ps | ≤0.10 | ||||
Directivity | dB | ≥50 | ||||
Power Handling | mW | 300 | ||||
Operating Temperature | ℃ | -0~+75(commercial) or -40~+85(Industrial) | ||||
Storage Temperature | ℃ | -40 ~ +85 | ||||
Package Dimension | mm | L100 x W80 x H10 | L120 x W80 x H18 | |||
Note:
Insertion loss excluding connector loss.
Customized dimension is available.
T&S Exhibited at 20th CIOE in Shenzhen
10 Sep 2018
The 20th CIOE held in Shenzhen from September 5 to 8. As a local company, T&S has exhibited at CIOE for years in a row.
T&S Listed on Shenzhen Stock Exchange
28 Dec 2016
T&S was listed on Shenzhen Stock Exchange officially at the hall of Shenzhen Stock Exchange on Dec.6, 2016. (Stock code: 300570) Chairman of the board Zhang zhimin.
The Seminar on Optical Interconnection Technology and Application of Data Center Successfully Concluded
23 Sep 2020
On September 10th, the seminar themed "Data Center Optical Interconnection Technology and Application" was successfully held in Shenzhen International Convention and Exhibition Center. Leade...