Dolph Microwave manufactures a quality line of flexible twistable/non-twistable waveguides, specially designed to meet all of your requirements. The components is made from a helically wound waveguide core and additional mechanical support is offered from a variety of protective jackets.
The Flexible Waveguide is parts of Feeder line, compared with the rigid waveguide, which is not only reduces the difficulty of connection, but also keep connection accuracy. The Rectangular Flexible Waveguide has E bend and H bend function including twisted function.
Ordering Information of Flexible Twistable Waveguide

Ordering Information of Flexible Non-twistable Waveguide

Flange type: Multiple types available - see Dolph Microwave Flanges page.
ELECTRICAL SPECIFICATIONS | |||||||||||||||||||
Waveguide Designation | Freq.Range (GHz) | Insertion Loss(dB/m) | Suggested Power Limit | Return Loss (dB) | |||||||||||||||
Peak(MW) | Average(KW) | 300mm | 600mm | 900mm | 1000mm | 1200mm | 1500mm | 1800mm | |||||||||||
R40 | WR229 | WG11A | 3.22-4.90 | 0.15 | 1.6 | 5 | 31.0 | 28.8 | 28.3 | 28.3 | 27.8 | 27.3 | 26.3 | ||||||
R48 | WR187 | WG12 | 3.94-5.99 | 0.16 | 1.4 | 3 | 31 | 28.8 | 28.3 | 28.3 | 26.4 | 23.1 | 21.7 | ||||||
R58 | WR159 | WG13 | 4.64-7.05 | 0.18 | 0.6 | 2.5 | 31 | 28.3 | 27.8 | 27.8 | 26.4 | 23.1 | 21.7 | ||||||
R70 | WR137 | WG14 | 5.38-8.17 | 0.25 | 0.56 | 2 | 30.2 | 27.8 | 27.3 | 27.3 | 26.4 | 23.1 | 21.7 | ||||||
R84 | WR112 | WG15 | 6.57-9.99 | 0.3 | 0.33 | 1.5 | 30.2 | 27.3 | 27.1 | 27.1 | 26.4 | 23.1 | 21.7 | ||||||
R100 | WR90 | WG16 | 8.20-12.5 | 0.4 | 0.22 | 1 | 30.2 | 27.1 | 27 | 27 | 25.2 | 22.1 | 19.7 | ||||||
R120 | WR75 | WG17 | 9.84-15 | 0.5 | 0.18 | 0.75 | 29.4 | 27 | 26.4 | 26.4 | 24 | 20.93 | 19.7 | ||||||
R140 | WR62 | WG18 | 11.9-18 | 0.65 | 0.12 | 0.4 | 29.4 | 26.4 | 26 | 26 | 24 | 20.93 | 19.7 | ||||||
R220 | WR42 | WG20 | 17.7-26.5 | 1.2 | 0.045 | 0.1 | 23 | 22.1 | 21.1 | 21.1 | - | - | - | ||||||
R320 | WR28 | WG22 | 26.5-40 | 2 | 0.022 | 0.075 | 21 | 20.8 | 20.8 | 20.8 | - | - | - | ||||||
R400 | WR22 | WG23 | 33-50 | 2.5 | - | - | 20 | 16.5 | 15.6 | 16 | - | - | - | ||||||
MECHANICAL SPECIFICATIONS | |||||||||||||||||||
Waveguide Designation | Max Twist(Deg/m) | Min E-Bending Radii(mm) | Min H-Bending Radii(mm) | ||||||||||||||||
Static | Repeated | Static | Repeated | Static | Repeated | ||||||||||||||
R40 | WR229 | WG11A | 132 | 33 | 165 | 660 | 330 | 1320 | |||||||||||
R48 | WR187 | WG12 | 155 | 40 | 136 | 544 | 272 | 1088 | |||||||||||
R58 | WR159 | WG13 | 185 | 45 | 116 | 464 | 232 | 928 | |||||||||||
R70 | WR137 | WG14 | 210 | 52 | 100 | 400 | 200 | 800 | |||||||||||
R84 | WR112 | WG15 | 260 | 68 | 82 | 328 | 164 | 656 | |||||||||||
R100 | WR90 | WG16 | 315 | 76 | 66 | 264 | 132 | 528 | |||||||||||
R120 | WR75 | WG17 | 365 | 92 | 54 | 216 | 108 | 432 | |||||||||||
R140 | WR62 | WG18 | 445 | 112 | 46 | 184 | 92 | 368 | |||||||||||
R220 | WR42 | WG20 | 630 | 157 | 30 | 120 | 60 | 240 | |||||||||||
R320 | WR28 | WG22 | 920 | 230 | 20 | 80 | 40 | 160 | |||||||||||
R400 | WR22 | WG23 | 920 | 230 | 18 | 78 | 38 | 158 | |||||||||||
*The Standard Model Numbers above are the most common parts ordered for size, material and flange. However, these models can easily be altered to accommodate your needs by using the Model # code system below for complete part number.
** Please refer to the Technical Reference section for flange types/connectors details. Please contact us for your specific requirements.
Waveguide Type: Twistable or non-twistable.
Waveguide Size: WR137, WR112, WR90, WR75 or others.
Insertion Loss and VSWR: unit in dB.
Length: 300, 500, 900, 1200, 1800 or other length in mm.
Flange type: Flat or groove or chock.
Hardware kits: Required or self preparation.
Any special requirement, please offer the drawing or dimension for checking.
Flexible waveguide normally is for connecting different kinds of two components. It is often together used with rigid waveguide systems especially if it cannot be located or positioned well. Flexible waveguide advantages offered is well outweigh the electrical performance limitations which is easy for flange and waveguide port change position. In other words is allow for mechanical movement.